Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Oral Maxillofac Surg ; 28(1): 63-77, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37266797

RESUMO

PURPOSE: To evaluate and compare the reported sinusitis occurrence after the sinus lift procedure and zygomatic implant placement. METHODS: This meta-analysis has been registered at PROSPERO. Studies were searched on six databases. Two authors screened titles and abstracts and fully analyzed the studies against the inclusion and exclusion criteria. The RoB 2.0 and the ROBINS-I tools were used to assess the quality and risk of bias of the included studies. The random-effects model was used for the meta-analysis. The prevalence of sinusitis was calculated based on the total of patients. Subgroup analysis was performed by sinus lift or zygomatic implant surgery technique. RESULTS: The search identified 2419 references. After applying the inclusion criteria, 18 sinus lift and 9 zygomatic implant placement studies were considered eligible. The pooled prevalence of sinusitis after sinus lift procedure was 1.11% (95% CI 0.30-2.28). The prevalence after zygomatic implant placement was 3.76% (95% CI 0.12-10.29). In the subgroup analysis, the lateral window approach showed a prevalence of sinusitis of 1.35% (95% CI 0.34-2.8), the transcrestal technique of 0.00% (95% CI 0.00-3.18), and the SALSA technique of 1.20% (95% CI 0.00-5.10). Regarding the techniques for zygomatic implant placement, the sinus slot technique showed a prevalence of 21.62% (95% CI 9.62-36.52) and the intrasinus technique of 4.36% (95% CI 0.33-11.08), and the prevalence after the extrasinus technique was 0.00% (95% CI 0.00-1.22). CONCLUSION: The sinusitis occurrence rate was higher after zygomatic implant placement than after sinus lift procedure and this occurrence was different depending on the used technique.

2.
Braz. dent. sci ; 26(2): 1-9, 2023. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1425975

RESUMO

Aim: The present split-mouth case report aims to describe the clinical and radiographic long-term outcomes of the implant rehabilitation of two mandibular premolars in which the digital workflow was used to apply different prosthetic protocols. Case description: A female 42-year-old patient with the absence of both mandibular second premolars was submitted to guided surgery for the placement of platform-switching Grand Morse connection implants. Digital workflow was used for implant and prosthetic planning, applying early loading protocol 21 days after surgery. The implant on the right side received the final abutment at the time of surgery (without loading), whereas the implant on the left side had a healing abutment placed, which was replaced by a temporary abutment and then by a final abutment. Two months after surgery, both implants had final ceramic restorations delivered. The patient was followed clinically and radiographically for 30 months, presenting excellent hard and soft tissue outcomes, with bone level changes lower than 2mm for both implants. Conclusion: The use of digital workflow and early loading, made the present implant-supported rehabilitation predictable, safe and time-efficient, resulting in total patient satisfaction. Peri-implant bone level was observed to be stable after early loading protocol for both platform-switching connection implants inserted, despite the prosthetic protocol applied.(AU)


Objetivo: O presente relato de caso de boca dividida tem como objetivo descrever os resultados clínicos e radiográficos a longo prazo da reabilitação com implante de dois pré-molares inferiores em que o fluxo de trabalho digital foi usado para aplicar os conceitos de "one abutment-one time" em uma das reabilitações e troca de componente no outro. Descrição do caso: Paciente do sexo feminino, 42 anos, com ausência de ambos os segundos pré-molares inferiores, foi submetida à cirurgia guiada para colocação de implantes de conexão Grand Morse plataforma-switching. Foi utilizado fluxo de trabalho digital para planejamento de implante e prótese, aplicando protocolo de carga antecipada 21 dias após a cirurgia. O implante do lado direito recebeu o componente protético definitivo no momento da cirurgia (sem carga), enquanto o implante do lado esquerdo recebeu um cicatrizador, que foi substituído por um pilar provisório e depois por um componente definitivo. Dois meses após a cirurgia, ambos os implantes tiveram restaurações cerâmicas finais entregues. A paciente foi acompanhada clínica e radiograficamente por 30 meses, apresentando excelentes resultados de tecidos duros emoles, com alterações do nível ósseo inferiores a 2mm para ambos os implantes. Conclusão: O fluxo de trabalho digital e carregamento precoce, tornou a presente reabilitação implantossuportada previsível, segura e eficiente em termos de tempo, resultando em total satisfação do paciente. O nível ósseo peri-implantar foi observado como estável após o protocolo de carregamento inicial para ambos os implantes de conexão plataforma-switching inseridos, independente do protocolo protético aplicado. (AU)


Assuntos
Humanos , Feminino , Adulto , Próteses e Implantes , Implantes Dentários , Perda do Osso Alveolar , Satisfação do Paciente , Desenho Assistido por Computador
3.
Clin Case Rep ; 10(8): e6248, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36034604

RESUMO

Narrow-diameter implants (≤3.5 mm) have been proposed to address the challenge of implant placement in cases of insufficient bone quantity, thin alveolar crest, and small cervical diameter teeth replacement The aim of this study is to report one-year outcomes of extra-narrow implant rehabilitation of maxillary lateral incisors, due to agenesis, in a young adult that presented sites with reduced mesiodistal and buccolingual dimensions. A 26-year-old male patient in need of fixed-implant supported prostheses due to the absence of permanent maxillary lateral incisors and with limited space, was submitted to surgery to receive two 2.9 mm hybrid Morse taper connection implants with hydrophilic surfaces. Immediate loading was applied by means of insertion of provisional prostheses, which were replaced for all-ceramic prostheses 12 months after surgery. The 1 year follow-up showed clinical and radiographic success of extra-narrow implant rehabilitation. Also, both regions presented good evolution of peri-implant esthetics, as assesses using the pink esthetic score, with improvements at 4 months follow-up and reaching high scores 12 months after surgery. Although the prosthetic rehabilitation of maxillary lateral incisors is challenging due to limited space for the insertion of implants, the clinical case suggests that the use of extra-narrow Morse Taper implants with hybrid design and hydrophilic surface is a reliable alternative, presenting good outcomes regarding hard and soft tissue and it is a versatile solution or immediate loading procedure. Further studies are needed to confirm extra-narrow implant predictability.

4.
J Appl Oral Sci ; 30: e20220089, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35920448

RESUMO

OBJECTIVE: This study aimed to retrospectively collect clinical data to evaluate the influence of possible risk factors on the long-term success of implant treatment with extra-narrow (2.9 mm diameter) implants in a daily dental practice setting. METHODOLOGY: Data were collected from records of patients who received at least one extra-narrow implant from 2012 to 2017, regarding implant survival, prosthesis survival, patient characteristics, and implant characteristics. The association between the dependent variables "implant survival", "prosthesis survival," and "adverse events" related to patient and implant characteristics was statistically evaluated by chi-square tests. Moreover, implant and prosthesis survival were analyzed by Kaplan-Meier survival curves. RESULTS: The sample was constituted of 58 patients (37 women and 21 men) with a mean age of 54.8 years old (SD: 12.5), followed up for up to eight years. In total, 86 extra-narrow implants were placed within this sample. Four implants were lost, resulting in an implant survival rate of 95.3%. A total of 55 prostheses were inserted and only one (1.8%) was lost, resulting in a prosthesis survival rate of 98.2%. The mean implant and prosthesis survival time was, respectively, 7.1 years and 6.3 years, according to the Kaplan-Meier survival analysis. A correlation was found between smoking and implant loss, which makes implant loss eight times more likely to occur in smokers than non-smokers. A significant association was also found between prosthesis loss and previous need of prosthesis repair. However, it was not considered clinically relevant. No association was found between the occurrence of adverse events and later implant or prosthesis loss. CONCLUSION: High implant and prosthesis survival rates were found in the long term for treatment with extra-narrow implants. Moreover, a significant correlation between smoking and implant loss was observed.


Assuntos
Perda do Osso Alveolar , Implantes Dentários , Perda do Osso Alveolar/etiologia , Implantação Dentária Endóssea/métodos , Implantes Dentários/efeitos adversos , Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante , Falha de Restauração Dentária , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Estudos Retrospectivos , Fatores de Risco
5.
Case Rep Dent ; 2022: 7525837, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35186336

RESUMO

BACKGROUND: This report presents a clinical case in which the CAD-CAM technology was applied to optimize a complex partial rehabilitation with implant-supported prostheses of a patient with several functional and aesthetic issues. Case presentation. A 40-year-old patient with several complaints due to the absence of multiple teeth and great dissatisfaction regarding his oral health was referred to a Dental College (Curitiba, Brazil). Guided surgery of 11 implants was planned. Digital flow and immediate loading protocol were applied. The patient was followed up for 2 years presenting good clinical and radiographic outcomes. CONCLUSIONS: The digital flow brought agility and precision to implant placement, immediate provisionalization added to satisfaction in the provisional phase, and CAD/CAM technology provided predictability and comfort to deliver the definite restorations.

6.
J. appl. oral sci ; 30: e20220089, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1386008

RESUMO

Abstract Objective This study aimed to retrospectively collect clinical data to evaluate the influence of possible risk factors on the long-term success of implant treatment with extra-narrow (2.9 mm diameter) implants in a daily dental practice setting. Methodology Data were collected from records of patients who received at least one extra-narrow implant from 2012 to 2017, regarding implant survival, prosthesis survival, patient characteristics, and implant characteristics. The association between the dependent variables "implant survival", "prosthesis survival," and "adverse events" related to patient and implant characteristics was statistically evaluated by chi-square tests. Moreover, implant and prosthesis survival were analyzed by Kaplan-Meier survival curves. Results The sample was constituted of 58 patients (37 women and 21 men) with a mean age of 54.8 years old (SD: 12.5), followed up for up to eight years. In total, 86 extra-narrow implants were placed within this sample. Four implants were lost, resulting in an implant survival rate of 95.3%. A total of 55 prostheses were inserted and only one (1.8%) was lost, resulting in a prosthesis survival rate of 98.2%. The mean implant and prosthesis survival time was, respectively, 7.1 years and 6.3 years, according to the Kaplan-Meier survival analysis. A correlation was found between smoking and implant loss, which makes implant loss eight times more likely to occur in smokers than non-smokers. A significant association was also found between prosthesis loss and previous need of prosthesis repair. However, it was not considered clinically relevant. No association was found between the occurrence of adverse events and later implant or prosthesis loss. Conclusion High implant and prosthesis survival rates were found in the long term for treatment with extra-narrow implants. Moreover, a significant correlation between smoking and implant loss was observed.

7.
Clin Case Rep ; 9(12): e05118, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34917363

RESUMO

This case report describes the treatment of two patients who presented with single edentulous sites in the region of upper premolars and were rehabilitated through the placement of injection-molded 2-piece zirconia implants and immediate single crowns. Three months after surgery, definitive prostheses were confectioned through digital workflow. Both patients were followed for 12 months during which clinical and radiographic implant success were observed, concerning implant stability, absence of peri-implantitis signs, complete implant osseointegration, good marginal bone-level maintenance, and excellent soft tissue esthetics. No biological or mechanical complications were observed within this period.

8.
Odontology ; 109(4): 965-972, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34146176

RESUMO

BACKGROUND: The aim of this retrospective study was to evaluate mid-term implant and prosthesis survival in patients with edentulous atrophic maxillae submitted to zygomatic implant-supported fixed rehabilitation and to identify possible related risk factors. METHODS: Data were collected from records of patients with edentulous atrophic maxillae, in good general health and who were rehabilitated by means of acrylic resin full-arch screw-retained prosthesis supported by at least one zygomatic implant, between the years of 2006-2017. Implant and prosthesis survival rates were calculated. The association between implant and prosthesis loss and quantitative and qualitative variables of interest was verified with t tests and Fisher's exact tests, respectively. For the significant variables in the latter, odds ratio and 95% confidence intervals were additionally calculated. RESULTS: The sample comprised 66 patients in whom 171 zygomatic implants were placed to support maxillary screw-retained full-arch prostheses. Implant and prosthesis survival rates of 94.15% and 92.4%, respectively, were observed in a mean of 3.6 years of follow-up (up to 11.7 years). Implant loss was 4.33 more likely to occur when adverse events were recorded after the procedure of implant placement (P = 0.026) and 10.31 more likely to occur in implants that had their prosthesis repaired during follow-up visits (P = 0.004). Prosthesis loss was 22.00 times more likely to occur when implants were previously lost (P < 0.001). All prostheses that were considered as failures (i.e. were replaced) had been previously submitted to laboratory repair at some point during follow-up. CONCLUSIONS: Zygomatic implant rehabilitation demonstrated to be a reliable method with good mid-term results. The occurrence of post-surgical adverse events and need for laboratory repair of the prosthesis were found to be significant risk factors for implant loss. Previous implant loss was significantly associated with prosthesis loss. These risk factors may be prevented by means of detailed planning of the rehabilitation to be carried out, including post-operative care of the patients, so that treatment success using zygomatic implants can be achieved.


Assuntos
Implantes Dentários , Arcada Edêntula , Implantação Dentária Endóssea , Prótese Dentária Fixada por Implante , Seguimentos , Humanos , Arcada Edêntula/cirurgia , Falha de Prótese , Estudos Retrospectivos , Zigoma/cirurgia
9.
Braz. dent. sci ; 24(3): 1-7, 2021. tab
Artigo em Inglês | BBO - Odontologia, LILACS | ID: biblio-1281776

RESUMO

Objective: The aim of this study was to evaluate implant and prosthesis survival rates in full-arch rehabilitation supported by implants with platform-switched Morse taper connection submitted to immediate or delayed loading, after up to 5 years of follow-up. Material and Methods: Data was retrospectively collected from clinical records of patients who were treated by means of implant-supported full-arch rehabilitation. Survival rates of implants and prostheses were evaluated according to immediate or delayed loading. Results: The sample comprised 967 implants. Of those, 627 were submitted to immediate loading (IL) while 340 to delayed loading (DL). After a follow-up period of up to 5 years, the implant survival rate for IL was of 99.7% (622/627 implants) and 97.2% (333/340 implants) for DL. The overall implant survival rate was 98.8% (955/967 implants). Prosthesis survival rate was 100% (N = 178) for both groups. Significantly more implants in the DL group presented bone loss (p > 0.01), either greater or lower than 2 mm, during the follow-up period. Conclusion:Within their limits, the present results suggest that full-arch rehabilitation with platform-switched Morse taper connection implants can lead to surgical and prosthetic predictable outcomes. Moreover, immediate loading protocol seems to be a good option for the rehabilitation of fully edentulous patients, as it involves a shorter treatment time, which may lead to greater patient satisfaction. (AU)


Objetivo: O objetivo deste estudo foi avaliar as taxas de sobrevivência de implantes e próteses em reabilitações de arco completo suportadas por implantes de conexão cone Morse e platform switching submetidos à carga imediata ou tardia, após até 5 anos de acompanhamento. Material e Métodos: Os dados foram coletados retrospectivamente em prontuários clínicos de pacientes que foram tratados por meio de reabilitação de arco completo suportada por implantes. As taxas de sobrevivência de implantes e próteses foram avaliadas de acordo com a carga imediata ou tardia. Resultados: A amostra foi composta por 967 implantes. Destes, 627 foram submetidos à carga imediata (IL) e 340 à carga tardia (DL). Após um período de acompanhamento de até 5 anos, a taxa de sobrevivência de implantes para IL foi de 99,7% (622/627 implantes) e de 97,2% (333/340 implantes) para DL. A taxa de sobrevivência geral dos implantes foi de 98,8% (955/967 implantes). Taxa de sobrevivência da prótese de 100% (N = 178) foi encontrada para ambos os grupos. Significantemente mais implantes no grupo DL apresentaram perda óssea (p > 0,01), seja maior ou menor que 2 mm, durante o período de acompanhamento. Conclusão: Os presentes resultados sugerem, dentro de seus limites, que a reabilitação de arco completo com implantes de conexão cone Morse e platform switching pode obter resultados cirúrgicos e protéticos previsíveis. Além disso, o protocolo de carga imediata parece ser uma boa opção para a reabilitação de pacientes totalmente edêntulos, pois envolve um menor tempo de tratamento, o que pode levar a uma maior satisfação do paciente (AU)


Assuntos
Humanos , Reabilitação , Implantes Dentários , Taxa de Sobrevida , Estudos Retrospectivos
10.
Int J Oral Maxillofac Implants ; 35(4): 757-761, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32724928

RESUMO

PURPOSE: The aim of this retrospective study was to report the survival rate of a novel hybrid hydrophilic dental implant design for all bone types. MATERIALS AND METHODS: This study evaluated the data collected from patients who received at least one implant to support a full-arch, partial, or single-crown dental rehabilitation in the maxilla or mandible. Implant survival rate was evaluated according to the clinical area and bone type, loading protocol, implant length and diameter, and placement torque. RESULTS: A total of 453 tapered hybrid implants placed in 101 patients (mean age: 56.39 ± 12.98 years) were evaluated, and the survival rate was 99.6%. The follow-up period was up to 24 months. Regarding bone quality, types I, III, and IV presented a 100% survival rate, whereas type II presented a 99.3% survival rate. The vast majority of implants were immediately loaded (443 implants), which achieved placement torques between 32 and 60 Ncm or higher, and presented an implant survival rate of 99.5%. CONCLUSION: An overall survival rate of 99.6% was found for hydrophilic hybrid dental implants when placed in all bone types, and no statistically significant difference was observed between them. However, further studies should be necessary to confirm these preliminary results.


Assuntos
Perda do Osso Alveolar , Implantes Dentários , Carga Imediata em Implante Dentário , Adulto , Idoso , Implantação Dentária Endóssea , Prótese Dentária Fixada por Implante , Falha de Restauração Dentária , Seguimentos , Humanos , Maxila/cirurgia , Pessoa de Meia-Idade , Estudos Retrospectivos , Taxa de Sobrevida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...